Templates, Tools and Utilities for Clarion Developers
|
|
|
|
Add a comment to an Icetips Article
Please add your comments to this article.
Please note that you must provide both a name and a valid email address in order
for us to publish your comment. Comments are moderated and are not visible until they have been approved. Spam is never approved!
Back to article list
Search Articles
Add Comment
Printer friendly
Direct link
Windows API: Item method implementation in OLE
2004-01-10 -- Michael Ware
Newsgroups: softvelocity.clarion.language
Jim,
Brilliant Thanks!! Using your tips I can now check the state of a service using:
! Check if the "Schedule" Service is running.
?ocxobject{prop:reportexception}=true
?ocxobject{prop:create}='WbemScripting.SWbemLocator'
objsvs=?ocxobject{'connectserver(,,,,,,,)'}
OBJSub = ?OcxObject{objsvs & '.GET(Win32_Service.Name=''Schedule'')'}
Message('service.NAME:' & ?OcxObject{OBJSub & '.NAME'})
Message('service.State:' & ?OcxObject{OBJSub & '.State'})
Message('service.Start Mode:' & ?OcxObject{OBJSub & '.StartMode'})
Message('service.Status:' & ?OcxObject{OBJSub & '.Status'} )
?ocxobject{prop:release}=OBJSub
?ocxobject{prop:release}=OBJsvs
But I've reached the end of my rope trying to implement calls to _newenum. The
following returns an IDispatch object into objEnum. But any attempt to access it
through the OLE control GPF.
objOS = (?OcxObject{objsvs & '.ExecQuery("Select * from Win32_QuickFixEngineering")'})
Message('OS=' & objOS) ! shows "`5474248"
BIND('IDispInterface',IDispInterface)
objEnum = ?OcxObject{objOS & '._newenum(&IDispINTERFACE)'}
objEnum[1] = '`' ! (replace chr(0) so this looks like a prop:object)
Message('Enum=' & objEnum) ! shows "`5474064"
BIND('objNxtArray',objNxtArray)
BIND('lNxtCount',lNxtCount)
objItem = ?OcxObject{objEnum & '.Next(1,&objNxtArray,&lNxtCount)'} !GPF
I suspect you had a good reason for using "a bit of assembler". . I'm going to
move on and try to get a "small" VB or VC exe that I can shell too to pull the data.
My targets here are the hot fixes (Win32_QuickFixEngineering) and OS data
(Win32_OperatingSystem).
Thanks again for the support. If anyone wants to FAQ the code for getting Service
data feel free.
-Mike
"jim kane" wrote in message
news:A921.1072838395.5597@discuss.softvelocity.com...
> I looked more closely at what you had done and looked back at some work on
> wmi I did a long, long time ago. I was very fortunate on that project as
> the network admin set everything up and wrote all the ldap queries.
>
> In any case the getobject is a com interface method. You're in essence
> trying to start in the middle of the story. The 1st step which your not
> doing is to use the wmi locator to connect to a wmi server. BTW the wmi
> services need to be running.
> The code to do that is:
> COUNT LONG
> objsvs cstring(20)
> objos cstring(20)
> CODE
>
>
> OPEN(MainWin)
> DISPLAY
> ACCEPT
> CASE EVENT()
> OF EVENT:OpenWindow
> ?ocxobject{prop:reportexception}=true
> ?ocxobject{prop:create}='WbemScripting.SWbemLocator'
> objsvs=?ocxobject{'connectserver(,,,,,,,)'}
>
> OF EVENT:Accepted
> CASE FIELD()
> OF ?Exit
> POST(EVENT:CloseWindow)
> OF ?GetOS
> objos = (?OcxObject{objsvs & '.ExecQuery("Select * from
> Win32_OperatingSystem")'})
> Message('ObjOS: '& objos)
> message(?ocxobject{objos & '.count'}) !displays '1'
> ?ocxobject{prop:release}=objos
>
> the next important thing is that you get OLE view and open the typelibary.
> it's in the same folder as the .dll and called WBEMDISP.TLB - if you search
> your hard drive you have it.
> if you open in in ole view and search for the execquery method you will find
> it returns a ISWbemObjectSet. As you pointed out earlier that object's item
> method is difficult to work with. The way arround that is the object has a
> _newenum method. VB supports that with the 'for each' syntax but clarion
> does not. You can write your own code to call via IDispatch to get the
> IEnum interface returned by _NEWENUM and use it's next method to loop thru
> all the objects in the set. I have never needed to do that because usually
> the objects provide their own explicit next method or the item method is
> easier to use. I did do it once back when I was first starting with come
> using a bit of assembler I published long ago in clairon mag but have neve
> had a need to update it so I cant really help you. If you are serious about
> wmi you'll need to attack that beast.
>
> the call to .get that followed does not return the same type of object and
> the object returned is not a collection so .count or .item does not work on
> it. I did not look how to use the Iwbemobject type of object that it
> returns.
>
> As a final word of advice, you will need to constantly be thinking about
> each object you acquire and remember for call release to avoid memory leaks.
>
> Jim Kane
>
Today is November 23, 2024, 2:20 am This article has been viewed 35229 times.
Google search
has resulted in 218 hits on this article since January 25, 2004.
Back to article list
Search Articles
Add Comment
Printer friendly
|
|
|