Par2: Covering initial program load 1999-04-09 -- Peter Donovan We had the same problem with our apps, and did almost the same as you. But we made
our 'starter' app a DDE server, and when the 'real' app starts up, it sends an event to
the 'starter' app to tell it to shut down. So it doesn't matter how slow or fast our users
computers are, it always works just fine.